Improper anchorage can decrease your pocket size

Detect Issues

Significant damages noted at wall due to improper anchorage of door frame and failure of wall surface due to impact during door operation.

02

Describe Issues

Damage at walls has happened due to improper anchorage of door frame. If not rectified at the right time, it can further deteriorate wall condition along with separation of frame from wall surface during the impacts. This would lead to decrease in strength of walls and difficulty in smooth operation of door. Hence hampering occupants by adding repair cost and time.

Direct Solutions

We recommend masonry repair with fiber mesh & suitable additive.

Purpose of fiber mesh

It provides high strength and durability.

Proper filling around door frame provides firmness

Detect Issues

Gap noted around door frame.

Describe Issues

If these gaps are not filled with proper material, then fixing of the frame with wall will not be firm and will act as insect / termite hub. It may also lead to water seepage. Therefore it needs to be filled properly to avoid problems in future. Its rectification procedure is easy, cost effective and less time consuming.

Direct Solutions

We Recommend gaps to be filled with self expanding material.

Classic case of mystery water seepage from a false ceiling having a non-identifiable source

Waterproofing / Other Vendors’ Solution
Before MACJ – A Buyer’s Choice Team Inspection
Short term solution as source not identifiable
Damage to ceiling / upper floor
Repair time: 20 – 25 days
High Cost of repair – Rs.1,50,000.

How MACJ – A Buyer’s Choice team solves this with a minimum of fuss & cost but maximum of technology, knowledge, & experience.

Description:

Classic case of unidentifiable seepage in a Prayer Room Ceiling that would have resulted in short term solution at high cost of repair with property damage and a lot of time. MACJ – A Buyers Choice Home Inspections identifies the source and solves the problem with its 3L service philosophy – Long term solution – Low cost of Repair – Least destruction

Background:

MACJ – A Buyer’s Choice team observed the following on visiting client’s home (5th Floor Unit):

5th Floor:
Water droplets falling from the Prayer room ceiling approximately for the last six months.
Presence of water pocket / trapped water noted in the alcove of the Prayer room as inferred by infrared camera.

6th Floor:
As the water was coming from the ceiling of 5th floor, so it was expected that the source of water was at the floor above (6th Floor) where it had made the path from the left corner above the alcove ceiling. Also at the left side of the sixth floor wall, minor efflorescence was noted which indicated presence of soluble salts and moisture. The 6th floor had a Prayer Room directly above, an open balcony with plants, a window ledge and a bathroom at a distance surrounding it. The source could be from anywhere.

The water path on the floor indicating leak in the concealed drain pipe

Possible Alternatives:

MACJ team did thermal (infrared) scanning of the area to track the water path and possible source of the leak. It was noted at 6th floor, an Air conditioner (Split AC) was installed on right side which had water drainage. The Drain line was a long concealed pipe running across the marble floor from right side to left side where the air conditioner drainage had been given in the balcony. Only the starting and end points were visible.

Apparently the Air conditioner pipe in 6th Floor either had a leak or an improper joint from where the air conditioner water was leaking.

Alternative Non-Destructive Testing (NDT) – Substantiation:

MACJ carried out NDT along with Deductive reasoning for making sure that the leak was from AC drain pipe. The team decided to pour 1.5 L of water in the starting point of the drain pipe and observed the ‘said end point’ for 15 minutes. But less than 500 ml water came out.

Eureka! Within that time frame, fall of water droplet in the affected area had increased. Hence more water was reaching the area due to leak/ improper joint at the drain pipe.

To substantiate our findings on Monday (15th may) we made alternate connection at the waste water drain pipe of the air conditioner at the sixth floor prayer room and requested our client i.e. the home owner to operate the air conditioner normally. 5th Floor: At fifth floor on the third day i.e. Wednesday (17th may) we observed the falling droplets reduced to bare minimum.
By Friday (19th may), as confirmed by our client the falling of water droplets had completely stopped.
On Saturday (20th may) it was reconfirmed that the droplets had stopped and the ceiling had reduced moisture.
6th Floor: On Saturday (20th may) we re-connected the waste water drain pipe of the air conditioner the way it was connected before.
5th Floor: By Monday (22nd May) water droplets started falling again. This reconfirmed that there was leak at the existing waste water pipeline of the sixth floor prayer room air conditioner.

Recommendations

Most of the current drain pipe was concealed under the finished wall and floor; hence it was not practical to replace that pipe. From a practical and economical point of view, we recommended to install a new drain pipe towards the room corresponding to the sixth floor air conditioner wall and then placing it towards the duct nearby. We recommended to use ½ inch rigid UPVC / CPVC pipe with company approved sealant only.

Conclusion:

A leak in the Air conditioner drainage pipe gave our client sleepless nights. Thanks to MACJ – A Buyer Choice experts, the issue was correctly and precisely identified with a simple solution. We should also applaud the client who proved wise enough to engage MACJ – A Buyers Choice Home Inspections to solve the problem. Not only did the MACJ team solved it successfully but also saved the client from major future damages which would have also resulted in incurring a lot of money. Our recommendations were also pocket friendly.

Waterproofing Company Solution Before MACJ Inspection MACJ – A Buyer’s Choice Solution after Inspection
Short term solution as source not identifiable Long term solution as the source of leak identified
Damage to ceiling / upper floor Non-destructive solution
Repair time: 20 – 25 days Repair time: 1 day
High Cost of repair – Rs.1,50,000 Low cost of repair – Rs.10,000

MACJ – A Buyer’s Choice Homes Inspections Motto:
LLL – Long term solution – Low cost of Repair – Least destruction

RERA Authority Holds Firm Position in Uttar Pradesh

RERA Uttar Pradesh

  • Uttar Pradesh notified the Real Estate (Regulation and Development) Rules on October 27, 2016.
  • The office of Regulatory Authority is located at Naveen Bhavan, Rajya Niyojan Sansthan, Kala Kankar House, Old Hyderabad, Lucknow – 226007.
  • Former chief secretary Rajive Kumar has been appointed the new full-time chairman of the Uttar Pradesh Real Estate Regulatory Authority (UPRERA)
  • Website Launched on 26th July, 2017.

A leakage can leak your savings

Detect Issues

Leakage noted at sink bottle trap.

08

Describe Issues

Waste water will not completely drain through outlet but will fall on the floor which will create unhealthy and unhygienic condition. Its repair on time, will help residents to keep their home clean, healthy and hygienic.

Direct Solutions

We recommend to reinstall the bottle trap with manufacturer’s specified gasket in the junctions.

Meaning / Purpose of Bottle trap

A bottle trap is provided to receive solid waste from washbasin, kitchen sinks and other appliances. This reduces the chance of drain blocking.

Let door sill guard your home against unwanted water

Detect Issues

Unit floor and external lobby area floor are at same level.

Describe Issues

As the floor of unit and external lobby are at same level, hence water and dust from floor lobby will enter inside unit. This will hamper the residents extremely in daily basis and they will be always facing difficulty with unwanted water and dust inside their house. Its rectification is very easy and cost effective.

Direct Solutions

We recommend to provide door sill of suitable size.

Meaning of door sill:

The horizontal piece of wood, stone, tile or metal at the threshold of a doorway.

Slow and Steady RERA taking Shape in Delhi NCT (National Capital Territory)

RERA Delhi

  • RERA Act, passed in Delhi on 26th March, 2016. Notification dated 26th March, 2016.
  • Notification dated 21st Nov. 2016, Shri Udai Pratap Singh, Vice Chairman, DDA (Delhi Development Authority) has been designated as Regulatory Authority for the purpose of the Act.
  • The office of Regulatory Authority is located at 14th Floor, Vikas Minar, ITO, New Delhi.
  • Rules Notified in Delhi dated 24th November, 2016.
  • RERA NCT Website launched. (Visit: www.dda.org.in/rera/)

Improper slope in bathroom – drains money instead of water

Detect Issues

Reverse slope noted around shower area grating.

Describe Issues

If slope is not provided in proper direction , then floor water will not get drained easily as it will flow opposite to floor drain outlet/grating. It will lead to water pockets at corners and lead to damp / seepage related issues in adjacent wall or floor surface. This will lead to damaged property / associated furniture and health issues. Moreover its  rectification  will cost large amount and time factor.

Direct Solutions

We recommend to review and if required, floor tiles to be relaid maintaining proper slope towards floor drain outlet and adequate strengthening of sealant at floor and wall tile junction.

Meaning of Slope

A surface of which one end or side is at a higher level than another; a rising or falling surface.

MACJ – A Buyer’s Choice Home Inspections India, Head office (Kolkata) Hosted Franchise Meet on 7th & 8th October, 2018

MACJ- A Buyer’s Choice Home Inspection India, Head office (Kolkata) Hosted Franchise Meet on 7th & 8th October, 2018. Where Franchises from all over India Participated.

The Following were discussed and brainstormed:

  • Present Status of the Business.
  • Challenges faced by Indian Partners.
  • Marketing Plans.
  • Strategy for Growth.

A Session on Inspection Training relating to Damp, Seepage and Moisture Assessment through Thermal Imaging Technology was conducted by the Kolkata Team.

by MACJ-ABCHI News

Monitor cracks as a warning signal for further deterioration

Detect Issues

Crack noted on wall at lintel height.

Describe Issues

Crack if not treated at right time, can increase in depth and lead to further deterioration in the affected area. This crack is non structural in nature. It will not cause any immediate affect to the occupants but can affect adversely in future. It also has negative aesthetic impression.

Direct Solutions


We recommend:
Step 1 : Making 2 mm groove along the crack till the depth of plaster.
Step 2 : Cleaning & Sealing the crack with ready to use ‘crack seal’ as per manufacturer’s specification.
Step 3 : Primer & paint finishing as per manufacturer’s specification.

Meaning of Lintel

A horizontal support of timber, stone, concrete, or steel across the top of a door or window.