Interior/ Exterior areas – Need specific type of paint

Detect Issues

Interior grade paint used in the outside of windows in external wall.

Describe Issues

Interior grade paint applied in outside of window can’t sustain weathering action for long period. Paints formulated for exterior use contain additives that give them longevity in the elements – including resistance to cracking and dirt resistance, as well as protection from the damage ultraviolet (UV) rays cause. Also exterior paints are made to combat against fading and mildew.
Different paints have different properties, and are formulated for different purposes. Usage of interior grade paint for external surface can cause deterioration of surface, due to which there are chances of moisture seepage which will add to high repair cost and inconvenience.

Direct Solutions

We recommend upgrading the same with exterior grade paint.

Unfilled gaps can be a source for moisture

Detect Issues

Gap noted in between rainwater outlet pipe & roof flooring.

Describe Issues

Rainwater outlet is duct wall mounted. Gap noted in between rainwater outlet pipe & roof flooring. This will cause rainwater to seep in through the gap between rainwater outlet pipe & roof flooring. If gap not uniformly sealed at right time, water will spread in attached/ associated areas below roof and cause severe damage in the long run. Thereby hassle residents in future with high repair cost and unhealthy living conditions.

Direct Solutions

We recommend floor outlet to be cleaned by wire brushing & uniform grouting with ’tile grout’/ non-shrink grout by professional plumber.

Don’t go for temporary solution, choose permanent one

Detect Issues

Door frame & wall junction sealed with putty filler.

Describe Issues

Both materials, i.e. door frame and wall, being different have different thermal movements. Putty being a rigid filler material, will peel off during operation of frame. This will create a moisture path, hence affecting the associated areas in long run. If not taken care at right time can generate a problem for occupants.

Direct Solutions

We recommend gap around frame along wall junction to be uniformly sealed with silicone sealant in dry condition as per manufacturer’s specification.

Plywood at external side can create a path for moisture

Detect Issues

Discoloration noted at wall under the window sill.

Describe Issues

As seen by infrared image flow of moisture noted from under the external sill. Ply wood is used under the window sill at external side & crack noted on it. Water seep-in noted from the plywood. Plywood makes the wood porous and susceptible to water damage. Thereby creating moisture path and causing discolouration at internal wall surface. If not rectified timely, moisture will spread and damage the entire wall.

Direct Solutions

We recommend chemical pasting of stone above the plywood with epoxy joint filling.

Carrom pocket earns point, water pocket drains money

Detect Issues

Water pocket noted near floor drain outlet.

Describe Issues

Inadequate slope at flooring can lead to formation of water pockets, hence floor water will not get drained easily from floor drain outlet and get accumulated at the corner. It will lead to damp/ moisture seepage related issues in adjacent areas, and also water seepage in the below floors. This can cause damage to property/ associated area and health issues in long run. Moreover its rectification will cost large amount and time factor.

Direct Solutions

We recommend client to review and if required, floor tiles to be relaid maintaining proper slope towards floor drain outlet and adequate strengthening of floor and wall tile junction with grout.

Inadequate pipe length can harass your neighbour

Detect Issues

Moisture patch noted on bathroom ceiling.

Describe Issues

In above floor’s bathroom, outlet pipe connecting in trap is short in length & spreading water in slab/ flooring bed mortar; this is creating moisture patch in below floor i.e where issue is detected. If not rectified at proper time, can further lead to spreading of moisture  in associated area and will lead to water dripping from ceiling at adjacent below storey. This will affect occupants by creating inconvenience due to heavy repair work as also unhealthy living condition.

Direct Solutions

We recommend :
1. short pipes to be extended using coupler/elbow by using solvent cement,
2. floor outlet to be cleaned by wire brushing & grouting by plumber with ’tile grout’/non-shrink grout.

Waterproofing at roof – can save wall closet

Detect Issues

Crack and peeling off laminate noted on wall closet.

Describe Issues

As seen by infrared images of both internal & external side of the affected area, flow of moisture noted from planter box at roof level. Roof Garden waterproofing system not found at planter box. If not rectified, moisture can spread in associated areas and further damage it & also laminate can be affected by termite.

Visual image

IR image

Roof Garden waterproofing system not found

Direct Solutions

We recommend installation of roof garden planter box waterproofing system.

Safety Hazard – Light point above gas stove provision

Detect Issues

One wall light provided above cook top gas stove provision.

Describe Issues

Light above gas stove position is unsafe as oil vapour from cooking will damage wire & fixture. If chimney is placed, light point will be unusbale. If not rectified at proper time, this can cause electrical & safety hazard for occupants.

Direct Solutions

We recommend to provide waterproof light fixture or changing the location of light before painting.

Even door frames have specific hinges

Detect Issues

Wooden door hinges used in aluminium door frame.

Describe Issues

Due to usage of wooden door hinges in aluminium door frame, stability of frame will get reduced with air pressure. Hence frame will get loose and panel will rattle. Moreover aluminium doors are designed to move door both ways, but due to usage of wooden hinges it will be not able to move both ways. It can create problem for residents in future.

Direct Solutions

We recommend review and replacing with aluminium door hinges / floor spring.

Fastener is key to Window Stability

Detect Issues

Screws used for fastening of window frame into wall.

Describe Issues

Usage of screws will reduce stability of the window frame as they are not designed for wind pressure. This can cause displacement of window frame which can create path for moisture and cause further damage. Additionally screws get easily rusted due to quality of its material. Hence this will add to the repair cost.

Direct Solutions

We recommend fitting of SS mechanical fastener with nylon plug.