Is your Home smelling bad? Check vent pipe


Detect Issues

WC vent pipe terminated inside false ceiling.


Describe Issues

As WC vent pipe is terminated inside false ceiling, it will spread fowl smell inside the unit & surrounding area. If not rectified, it will create unhealthy & unhygienic condition for residents.


Direct Solutions

We recommend extending the pipe above roof level in open to air environment.

Check gasket at window of your home


Detect Issues

Rubber gasket is incomplete at window panel.


Describe Issues

Gasket are used for covering the area between the window panel and frame to seal against wind, rain and other adverse weather conditions that may affect the function of the window. If not rectified, can create a path for unwanted water seepage. This will cause moisture related problems in the unit & also add extra cost and time factor for repairs.


Direct Solutions

We recommend replacing with full size gasket.

Do you know the Source & Cause of moisture on your ceiling?


Detect Issues

Presence of moisture at ceiling surface.


Describe Issues

As seen by infrared image flow of moisture noted from ceiling mid span towards wall. This moisture has originated from entrapped moisture under hollow roof tile surface which has intruded through the gap at tile joints in the adjacent roof area. If not rectified, hollowness can further lead to cracked tiles. Can lead to further problems in other associated or attached areas like damp/ seepage issues, will increase maintenance cost and create hassles for residents.


Direct Solutions

We recommend:
Step 1 – Tiles joint cutting with a suitable tool.
Step 2 – Preparation & pouring of high viscosity cement grout & adequate vibration to be made on floor tile with a rubber hammer during pouring.
Step 3 – Tile joint to be sealed with pigmented flexible tile grout.

Is your electric socket suitable for using a specific appliance?


Detect Issues

6 amps Switch socket provided for Geyser.


Describe Issues

As per current rating, Geyser requires current greater than 6 amps. Providing 6 amps switch socket instead of 16 amps will lead to damaged switch socket board and frequent tripping off MCB due to overheating. Hence, it can create electrical & safety hazard if not rectified on time.


Direct Solutions

We recommend replacement of 6 amp with 16 amps switch socket board for geyser.

Detect & Repair Concealed leakage to save money


Detect Issues

Concealed leakage from WC and soil pipe junction.


Describe Issues

Inadequate packing along WC and soil pipe junction can lead to leakage from the joint. If the leak is not rectified at the right time can lead to moisture intrusion and damage the associated/ attached areas. It will create a hassle for the residents in future by adding cost for repair of the leak and associated damage at the area.


Direct Solutions

We recommend, re-installation of WC with manufacturer specified gasket packing at soil pipe junction.

Fill the Junction Gaps to avoid moisture intrusion


Detect Issues

Gap between WC and wall.


Describe Issues

Splashed water entering through the gaps can infiltrate through bare masonry wall surfaces around provision for WC outlet and cistern inlet pipe. This can lead to spreading of moisture to the attached/ associated area which can lead to damage in future.


Direct Solutions

We recommend filling the gap with tile grout.

Upgrade to CPVC supply pipes for longevity


Detect Issues

Worn out GI pipe noted for supply line.


Describe Issues

Service life of current GI pipe is expired.
Unlike CPVC pipes, GI pipe is not corrosion resistant & compitable to hot or cold water and have more chances of bacterial growth. Hence, it gets worn out or deteriorated easily.


Direct Solutions

We recommend upgrading to CPVC pipes.

Protect your wooden door panel in rainy season


Detect Issues

Wooden door panel is rubbing and hitting the frame.


Describe Issues

No gap left/ made in between panel & frame after closing. This issue has happened as wood has a feature of seasonal expansion which can lead to door panel not getting closed in some cases or getting closed with pressure in others. This can create problems in rainy season.


Direct Solutions

We recommend maintaining uniform 3 mm gap all around with carpentry jack plane.

Beware! while choosing switch for AC


Detect Issues

Switch is used for air conditioner.


Describe Issues

In case of overloading in AC, starter will trip and hence will break the circuit whereas providing switch will lead to burning of AC motor. If not rectified at the right it can lead to electrical safety hazard in future, and also add an extra cost of repair or replacement.


Direct Solutions

We recommend to replace the Switch with adjustable amp AC Starter.

Home Inspection can save your home’s health


Detect Issues

Significant crack with hollowness at plaster surface noted on external masonry sill.


Describe Issues

Due to this crack on external sill, rainwater and moisture will enter masonry wall surface thereby affecting adjacent/ in-house wall surface and will weaken the integrity of associated elements. Additionally, if Crack not treated at right time, can increase in depth and lead to further deterioration at the affected area. Hence will hassle the residents by adding an extra cost and time factor due to its rectification or repair process.


Direct Solutions

We recommend:
Step 1 – Cracks with hollow plaster surface and loose material to be scrapped off till hard strata.
Step 2 – Re-plastering to be done with repair mortar.
Step 3 – After adequate curing of plastered surface, exterior grade paint finish to be provided as per paint manufacturer specifications.