Bore packing around Plumbing Pipes can save from seepage

Detect Issues

Bore packing is not provided around plumbing lines insertion at external side.

Describe Issues

If bore packing is not done around plumbing lines insertion at external side, then it will create a pathway for intrusion of external rainwater and moisture from air thereby affecting adjacent area wall surfaces. This will also cause damage in the interior elements due to moisture intrusion which can weaken its integrity. If not rectified at right time, it can further deteriorate the associated areas. Hence can hamper residents in long run by creating unhealthy living condition and adding an extra cost for repair works.

Direct Solutions

We recommend providing adequate bore packing around the plumbing pipe lines .

Meaning of Bore packing

Bore packing is the process of fixing Plumbing pipes in RCC members (Slabs or beams or RCC walls) in their cutouts/ core cuts.

Facing electrical problems – Get Electrical Inspection ASAP

Detect Issues

MCB to MCB, shorting bar not provided in Distribution Box.

Describe Issues

If shorting bar is not used at MCB, there are chances of current loss and can generate heat due to which equipment can also get heated.

This can lead to safety & electrical hazard.

Direct Solutions

We recommend fitting of Shorting bar to avoid current loss.

Meaning of MCB shorting bar

MCB shorting bar is a plate which is used to inter connect MCB phase line and this provides adequate contact point between MCB.

Choose Junction filler wisely to increase its longevity

Detect Issues

Rigid grout used in between counter & wall tiles.

Describe Issues

Tiles and counter stone being different materials show different movements due to thermal changes. Cement or other grout being a rigid filler material, gets cracked in long run. Use of sealant material will increase its longevity. Its application is easy and cost effective.

Direct Solutions

We recommend junction cleaning and uniformly sealing with general Purpose Clear Silicone Sealant in dry condition as per sealant manufacturer specifications after required scrapping off rigid grout material.

Do you know unfilled gaps can create severe damage?

Detect Issues

Gap around and between air conditioner drain pipe & sink outlet pipe inside floor drain outlet.

Describe Issues

Unfilled gaps will lead to water intrusion through it, thereby affecting the floors below. This will lead to further deterioration of wall and ceiling surfaces in associated areas below. Thereby will hamper residents in long run by adding an extra cost and time factor due to repair.

Direct Solutions

We recommend adequate grouting, using non shrinkable grout.

Safety concern – Socket close to geyser valve

Detect Issues

Geyser socket is close to geyser valve.

Describe Issues

Due to this position of geyser socket, during leakage of the geyser pipe or while maintenance water may spill over the socket board and cause short circuit. This can create safety & electrical hazard for residents in future. So its rectification is needed to be done early to be keep you and your home safe.

Direct Solutions

We recommend client to review and raise the height of the geyser socket.

Don’t wait for big expenditure – Replace leaking pipe

Detect Issues

Peeling off paint noted on front wall.

Visual Image

Thermal Image

Describe Issues


As seen by infrared images of both internal side & external side of affected area, flow of moisture noted from roof level. The moisture damage observed is mainly originated due to leak in pipe from Roof. As observed, moisture flow is in walls from roof level and hence damaged the surface. If not rectified soon, moisture will flow and damage the associated/ attached areas. This will hamper occupants by creating unhealthy living conditions and also create high cost of repair.

Direct Solutions

We recommend defective pipe to be replaced by plumber.

Proper grouting can be saviour for you and neighbour

Detect Issues

Moisture patch noted on balcony wall-ceiling junction.

Visual Image

Thermal Image

Describe Issues

As seen by infrared image moisture patch noted on balcony wall-ceiling junction & the same moisture is noted inside adjacent bedroom upper side of balcony door. The moisture is originated from above floor balcony outlet area; due to gap between floor outlet & flooring. This gap has become moisture seepage pathway and is spreading moisture in below floor. If this source of moisture is not rectified at proper time, will spread and damage the associated area further. Thereby will create difficulty for occupants by creating unhealthy living conditions and adding extra cost due to its repair.

Direct Solutions

We recommend floor outlet to be cleaned by wire brushing & grouting by plumber with ’tile grout’/ readymade repair mortar.

Protect your child from injury – improper window size

Detect Issues

Window is of long size with low window sill height.

Describe Issues

This window due to current size and low sill height would be a tripping hazard – a safety concern especially for children in homes. If not taken care, can be a safety hazard in future. Its rectification is easy and must be done for safety.

Direct Solutions

We recommend client to review and suitable aluminium tube to be fitted to act as guard rail.

We check standard codes for foods – why not for wires ?

Detect Issues

16A socket board fitted with non ISI marked 1.5 sq mm wire.

Describe Issues

As per standard 1.5 Sq mm is not advisable for 16 Amps socket. Additionally Non ISI marked wires are less fire resistant and have tendency to melt with high loads. They also do not have good insulation. Non ISI marked wires could have less longevity, are less safer and ecofriendly as compared to ISI marked wire. So, it is better to have ISI marked wires which will be a step towards safer home and also would be better in longer run.

Direct Solutions

We recommend to provide ISI marked wire with required gauge as per standard.

Do you have access to False Ceiling? It is needed!

Detect Issues

No trap door provision at false ceiling.

Describe Issues

Ceiling trap door is used in false ceilings to access plumbing pipes or valves, electrical conduit, AC gas pipe for service, maintenance, and repairs. It might appear a small problem but it is important to provide trap door in false ceiling as there can be chances of leakage in pipe or some problem in AC gas pipe insulation & electrical conduit, which can be easily repaired by providing for it. This will provide access to plumbing pipes, electrical conduit or AC pipe lines during repair which will be saviour for residents in future.

Direct Solutions

We recommend to provide a trap door provision of suitable size.